POWER GRID.
TRANSFORMED.
Power transformers from 25 to 2500 kVA and complete transformer substations KTP/KTPN/KTPB with a voltage of 0.4-10 kV. Dry for indoor use, oily for heavy loads.
Design according to DBN. Obtaining technical specifications from OSR. Turnkey installation and commissioning.
Problems of electricity supply in Ukraine
Aging transformer infrastructure, growing loads and new regulatory requirements create critical business risks. Old TPs cannot withstand modern capacities.
Worn out transformers
80% of transformers in Ukraine are older than 25 years. Increased losses, risk of accidents, oil leaks. The equipment is working at the limit of the resource.
Quality of electricity
Voltage drops, harmonic distortion, phase asymmetry. Sensitive equipment goes out of order, the number of defects increases.
Power limitations
Business is growing, but technical specifications do not allow to increase capacity. The old KTP has no reserve, and a new connection costs months of waiting.
New Grid Code requirements
The updated Connection Rules and the Code of Networks require the modernization of the RZA, accounting and automation. Non-compliance can result in fines and suspension.
Modern transformer solutions
The full cycle: from the inspection of the existing TP to the commissioning of the new equipment. Certified equipment, design according to DBN, warranty up to 5 years.
Dry transformers
No oil, no risk of fire. Ideal for premises: shopping centers, hospitals, data centers. Insulation class F/H. Minimal maintenance, service life 30+ years.
Oil transformers
Proven reliability for outdoor installation. Optimal price for capacities from 100 kVA. Hermetic and of expansion tank. GOST and IEC.
KTP turnkey
Complete transformer substations KTPN (external) and KTPB (block). Transformer + RP 10 kV + cabinets 0.4 kV + accounting + AVR automation in one housing.
Increasers for SES
Step-up transformers 0.4/10 kV for solar power plants. Coordination of the power of inverters by the point of connection to the OSP network.
Technical characteristics
Dry transformers
100-2500 kVA / 10/0.4 kV
- • Insulation class F (155°C) / H (180°C)
- • Degree of protection IP23 - IP54
- • XX losses: 0.15-0.25% of Rn
- • Fire safety, without oil
Oil transformers
25-2500 kVA / GOST, IEC
- • Hermetic / of expander
- • Transformer oil: class I
- • Service life: 25-30 years
- • TM, TMG, TMZ series
KTP (KTPN / KTPB)
Complete substations
- • Kiosks (KTPK) up to 1000 kVA
- • Blocks (KTPB) up to 2x2500 kVA
- • IP54 outdoor installation
- • Factory ready 95%
Switching equipment
RP 10 kV / Cabinets 0.4 kV
- • Vacuum switches 10 kV
- • AVR for 2 inputs + section
- • ASKOE (electricity accounting)
- • Microprocessor RZA
What is included in "Turnkey"?
- Examination of the existing TP
- Design according to DBN
- Obtaining technical specifications from OSR
- Delivery by special transport
- Installation and connection
- Testing and tuning
How to choose a transformer
Comparison of dry-type and oil-type transformers by key parameters for your facility
Application matrix
Rooms
Shopping center, shopping center, data centerOutside / Factory
Industrial zone, WarehouseSolar SES
Step-up 0.4/10 kVHospital
Critical infrastructureTransformer selection
Select the object parameters for preliminary calculation
For the plant, an oil transformer with an external installation of an oil receiver is recommended.
Frequently Asked Questions
Useful materials
Dry vs Oily: what to choose
Comparison of TCO, reliability and integration of BESS.
Integration of BESS into the industrial network
6 stages of connection: from audit to launch.
Energy Storage 2026: new rules
Changes to the Code of distribution and technical specifications for joining.
SES for business: real payback
Calculation of ROI for industrial SPPs in Ukraine.
Adjacent solutions
Industrial SES
Solar power plants of energy storage systems. Step-up transformers 0.4/10 kV for supplying power to the network.
Go to solutionIndustrial UPS
Uninterruptible power supplies for critical infrastructure. Uninterrupted power supply during input switching and network failures.
Go to solution