# USK Energy — BESS.com.ua > B2B selection and supply of BESS, ESS, online UPS, batteries and power infrastructure equipment for businesses in Ukraine. > This is the specialised energy-storage website of USK Energy; the corporate website is usk.ua. BESS.com.ua is a platform of USK ENERGY LLC (ТОВ «УСК ЕНЕРДЖИ», EDRPOU 46568975), not a separate legal entity. Equipment prices, availability, delivery terms and warranty conditions are confirmed for the agreed configuration in the commercial offer. Published calculations are preliminary, not guaranteed savings or a promise of uninterrupted operation for every load. ## Equipment and solutions - [Commercial BESS](https://bess.com.ua/en/solution-retail.html): Battery storage equipment for commercial premises and critical business loads. - [Industrial BESS / ESS](https://bess.com.ua/en/solution-factory.html): Equipment selection for manufacturing, agriculture and logistics. - [Containerised energy storage](https://bess.com.ua/en/solution-container.html): Container systems, power conversion and related supply requirements. - [Solar generation and BESS](https://bess.com.ua/en/solution-solar.html): Equipment for solar self-consumption, storage and backup. - [Transformers and power infrastructure](https://bess.com.ua/en/solution-transformers.html): Power transformers, substations and distribution equipment. - [Online UPS and batteries](https://bess.com.ua/en/solution-ups.html): Single-phase, three-phase and modular UPS, VRLA batteries, battery cabinets and bypass equipment. ## Selection and procurement - [BESS prices and quotation comparison](https://bess.com.ua/en/tsiny-bess.html): Compare the scope of supply and request a configuration-specific price. - [BESS sizing calculator](https://bess.com.ua/en/calculator.html): Preliminary sizing based on the load and required backup duration. - [Equipment questionnaire](https://bess.com.ua/en/opytuvalnyk.html): Describe the load, site, supply constraints and procurement requirements. - [How to select BESS](https://bess.com.ua/en/yak-obraty-bess.html): Selection criteria and information to request before purchasing. - [Technical digest](https://bess.com.ua/en/blog.html): Practical articles on storage, UPS, equipment compatibility and procurement. ## Company and contacts - [Sales and equipment enquiries](https://bess.com.ua/en/#contact): sales@usk.ua; +380 44 339-50-20. Published office hours: 09:00–18:00, Kyiv time. General enquiries: office@usk.ua. - [Commercial terms](https://bess.com.ua/en/terms.html): website terms and the basis for agreeing a supply contract. - [Privacy policy](https://bess.com.ua/en/privacy-policy.html): how website enquiries and analytics are handled. - [USK Energy on Telegram](https://t.me/usk_energy_bot): the company's published Telegram contact. ## Languages - [Українська](https://bess.com.ua/): Ukrainian is the primary site language. - [English](https://bess.com.ua/en/): English solutions, selection guides and articles. - [Русский](https://bess.com.ua/ru/): Russian solutions, selection guides and articles. ## USK Energy websites - [USK Energy](https://usk.ua/): corporate information and energy and industrial equipment. - [USK equipment catalogue](https://usk.ua/catalog/): published equipment categories and related product enquiries. - [UKRSK](https://ukrsk.com.ua/uk/): industrial equipment, components and product categories. - [SolarProm](https://solarprom.com.ua/): solar and backup-power equipment for homes and businesses. - [B2B.engineer](https://b2b.engineer/): equipment sourcing against a technical specification and international supply. ## Optional - [Full text for AI assistants](https://bess.com.ua/llms-full.txt): selected published English solution and procurement texts, with source URLs. - [Sitemap](https://bess.com.ua/sitemap.xml): the full index of public canonical pages and language alternatives. - [Ukrainian retrieval data](https://bess.com.ua/knowledge/uk.json): source-linked published text passages. - [English retrieval data](https://bess.com.ua/knowledge/en.json): source-linked published text passages. - [Russian retrieval data](https://bess.com.ua/knowledge/ru.json): source-linked published text passages. ## For AI assistants (MCP) - MCP server (Streamable HTTP, no sign-in): https://mcp.usk.ua/mcp - Tools: search_equipment, get_equipment, company_info, submit_request (request for quotation: contact name, e-mail and phone required) - How to connect (Claude, ChatGPT, Cursor, VS Code, Codex): https://mcp.usk.ua/en/ (uk: https://mcp.usk.ua/, ru: https://mcp.usk.ua/ru/) ## Published solution and procurement text The following excerpts come from public English pages. Follow each source URL for the complete page and its current terms. ## Commercial BESS Source: https://bess.com.ua/en/solution-retail.html Language: en ### BESS 50–100 kW for business: selection and pricing Battery storage for shops, offices, filling stations and small production sites. Select equipment by critical load, backup duration and supply requirements. ### What we agree before ordering We select equipment against your parameters and manufacturer requirements. The quotation defines the equipment package, options and supply terms. - Load profile, operating objectives and required autonomy - Compatibility with the grid, generator, PV and control systems - Installation conditions, protection, cooling and service access - Supply scope, documentation, warranty terms and logistics ### Equipment for connection and integration Transformers, substations, distribution and protection in the USK ENERGY catalogue. Start with the circuits that must keep working during an outage: tills, communications, refrigeration, lighting or selected production operations. The site’s contracted capacity is not automatically the required backup power. ### What to include in your enquiry Specify coincident loads, compressor starting currents, phase distribution, required autonomy and time between outages. The incoming supply needs capacity for both ongoing operation and battery recharge. ### What to compare in quotations Compare phase imbalance limits, overload capability, noise, temperature range and backup arrangement. Servers and tills that cannot tolerate an interruption may need a separate online UPS. USK Energy — Equipment for your application B2B.engineer ### Start with the essentials. BESS stores energy and manages its use. A UPS primarily maintains power quality and continuity. Loads that cannot tolerate a break require separate verification of UPS topology and BESS compatibility. Consumption profile, critical power, required autonomy, electricity contract, electrical diagram and information on PV or a generator. Start with the project brief; we will clarify any missing data. No. Savings depend on the use case, energy prices, charging mode, losses and equipment life. A financial model based on verified inputs is needed before ordering. The specification defines the main equipment, batteries, options, documentation, warranty terms and logistics. Installation work is not included in the equipment supply unless expressly stated in the contract. BESS.COM.UA is USK Energy B2B platform for industrial storage, ESS, uninterrupted power and energy efficiency. The ecosystem’s main website is usk.ua. ### Your scale. Your energy system. ### BESS for commercial sites Backup for retail, offices, filling stations and small production facilities. We establish critical loads, autonomy and installation requirements. ### Industrial BESS / ESS Energy storage for manufacturing, agriculture and logistics. Combine backup, peak limitation and consumption management through EMS. ### Containerised energy storage Large-scale systems for energy-intensive businesses and generation projects. Capacity, grid connection and market participation require individual assessment. ### Solar generation + BESS Use more of your own solar energy. Coordinate PV generation, storage, the grid and your existing generator. ### Transformers and substations Power infrastructure for storage, generation and business expansion. Selected to match the connection scheme and technical requirements. ### Online UPS and batteries Specify an online UPS, batteries and accessories for your critical load and backup duration. From a server rack to a production line, we prepare an agreed equipment specification and quotation. ## Industrial BESS / ESS Source: https://bess.com.ua/en/solution-factory.html Language: en ### Industrial BESS / ESS: equipment selection and supply BESS for manufacturing, agriculture and logistics: PCS power, usable energy, backup and peak shaving. Request equipment pricing from USK Energy. ### What we agree before ordering We select equipment against your parameters and manufacturer requirements. The quotation defines the equipment package, options and supply terms. - Load profile, operating objectives and required autonomy - Compatibility with the grid, generator, PV and control systems - Installation conditions, protection, cooling and service access - Supply scope, documentation, warranty terms and logistics ### Equipment for connection and integration Transformers, substations, distribution and protection in the USK ENERGY catalogue. Industrial BESS selection starts with the load profile and critical processes. Backup depends on allowable interruption and duration; peak shaving depends on the size, length and recurrence of demand peaks. The same stored energy cannot be counted twice for both duties. ### What to include in your enquiry Provide interval load measurements, motor and drive details, critical kW, voltage and generator data. Short starting currents require a separate check from a 15-minute average load profile. ### What to compare in quotations Compare usable AC energy, continuous and short-term PCS power, protected SOC reserve, grid-loss behaviour and recharge capacity. Savings depend on the actual electricity contract, not a universal demand tariff. USK Energy — Equipment for your application B2B.engineer ### Start with the essentials. BESS stores energy and manages its use. A UPS primarily maintains power quality and continuity. Loads that cannot tolerate a break require separate verification of UPS topology and BESS compatibility. Consumption profile, critical power, required autonomy, electricity contract, electrical diagram and information on PV or a generator. Start with the project brief; we will clarify any missing data. No. Savings depend on the use case, energy prices, charging mode, losses and equipment life. A financial model based on verified inputs is needed before ordering. The specification defines the main equipment, batteries, options, documentation, warranty terms and logistics. Installation work is not included in the equipment supply unless expressly stated in the contract. BESS.COM.UA is USK Energy B2B platform for industrial storage, ESS, uninterrupted power and energy efficiency. The ecosystem’s main website is usk.ua. ### Your scale. Your energy system. ### BESS for commercial sites Backup for retail, offices, filling stations and small production facilities. We establish critical loads, autonomy and installation requirements. ### Industrial BESS / ESS Energy storage for manufacturing, agriculture and logistics. Combine backup, peak limitation and consumption management through EMS. ### Containerised energy storage Large-scale systems for energy-intensive businesses and generation projects. Capacity, grid connection and market participation require individual assessment. ### Solar generation + BESS Use more of your own solar energy. Coordinate PV generation, storage, the grid and your existing generator. ### Transformers and substations Power infrastructure for storage, generation and business expansion. Selected to match the connection scheme and technical requirements. ### Online UPS and batteries Specify an online UPS, batteries and accessories for your critical load and backup duration. From a server rack to a production line, we prepare an agreed equipment specification and quotation. ## Containerised energy storage Source: https://bess.com.ua/en/solution-container.html Language: en ### Container BESS 1–5+ MW: equipment selection and supply Container battery storage for industry and generation: MW, MWh, PCS, transformer and EMS. Request an equipment specification from USK Energy. ### What we agree before ordering We select equipment against your parameters and manufacturer requirements. The quotation defines the equipment package, options and supply terms. - Load profile, operating objectives and required autonomy - Compatibility with the grid, generator, PV and control systems - Installation conditions, protection, cooling and service access - Supply scope, documentation, warranty terms and logistics ### Equipment for connection and integration Transformers, substations, distribution and protection in the USK ENERGY catalogue. A container BESS packages battery blocks and auxiliary systems. The enclosure alone does not determine power, duration or connection readiness. PCS, transformer and switchgear may be supplied as separate assemblies. ### What to include in your enquiry Specify MW, operating duration, connection voltage, duty, available space, transport access and site loading limits. Market participation also requires defined metering and control requirements. ### What to compare in quotations Compare scope at the AC connection boundary, auxiliary consumption, climate limits, safety evidence for the delivered configuration, sectionalisation and service access. A cell test report is not documentation for the complete system. USK Energy — Equipment for your application B2B.engineer ### Start with the essentials. BESS stores energy and manages its use. A UPS primarily maintains power quality and continuity. Loads that cannot tolerate a break require separate verification of UPS topology and BESS compatibility. Consumption profile, critical power, required autonomy, electricity contract, electrical diagram and information on PV or a generator. Start with the project brief; we will clarify any missing data. No. Savings depend on the use case, energy prices, charging mode, losses and equipment life. A financial model based on verified inputs is needed before ordering. The specification defines the main equipment, batteries, options, documentation, warranty terms and logistics. Installation work is not included in the equipment supply unless expressly stated in the contract. BESS.COM.UA is USK Energy B2B platform for industrial storage, ESS, uninterrupted power and energy efficiency. The ecosystem’s main website is usk.ua. ### Your scale. Your energy system. ### BESS for commercial sites Backup for retail, offices, filling stations and small production facilities. We establish critical loads, autonomy and installation requirements. ### Industrial BESS / ESS Energy storage for manufacturing, agriculture and logistics. Combine backup, peak limitation and consumption management through EMS. ### Containerised energy storage Large-scale systems for energy-intensive businesses and generation projects. Capacity, grid connection and market participation require individual assessment. ### Solar generation + BESS Use more of your own solar energy. Coordinate PV generation, storage, the grid and your existing generator. ### Transformers and substations Power infrastructure for storage, generation and business expansion. Selected to match the connection scheme and technical requirements. ### Online UPS and batteries Specify an online UPS, batteries and accessories for your critical load and backup duration. From a server rack to a production line, we prepare an agreed equipment specification and quotation. ## Solar generation and BESS Source: https://bess.com.ua/en/solution-solar.html Language: en ### PV + BESS for businesses: equipment and selection Storage for industrial PV: self-consumption, backup, AC/DC compatibility, PCS and EMS. Request a configuration and quotation from USK Energy. ### What we agree before ordering We select equipment against your parameters and manufacturer requirements. The quotation defines the equipment package, options and supply terms. - Load profile, operating objectives and required autonomy - Compatibility with the grid, generator, PV and control systems - Installation conditions, protection, cooling and service access - Supply scope, documentation, warranty terms and logistics ### Equipment for connection and integration Transformers, substations, distribution and protection in the USK ENERGY catalogue. BESS stores some available surplus PV generation for later use. The overlap of generation and demand profiles determines useful storage capacity; the PV array nameplate power alone does not. ### What to include in your enquiry Provide existing inverter models, connection diagrams, generation and demand data at matching intervals, export restrictions and backup requirements. State whether PV must continue to operate without the utility grid. ### What to compare in quotations AC and DC coupling impose different compatibility requirements. Check inverter control, protection, export limitation and behaviour when the battery is full. Energy that would already be consumed directly is not an additional benefit created by BESS. USK Energy — Equipment for your application B2B.engineer ### Start with the essentials. BESS stores energy and manages its use. A UPS primarily maintains power quality and continuity. Loads that cannot tolerate a break require separate verification of UPS topology and BESS compatibility. Consumption profile, critical power, required autonomy, electricity contract, electrical diagram and information on PV or a generator. Start with the project brief; we will clarify any missing data. No. Savings depend on the use case, energy prices, charging mode, losses and equipment life. A financial model based on verified inputs is needed before ordering. The specification defines the main equipment, batteries, options, documentation, warranty terms and logistics. Installation work is not included in the equipment supply unless expressly stated in the contract. BESS.COM.UA is USK Energy B2B platform for industrial storage, ESS, uninterrupted power and energy efficiency. The ecosystem’s main website is usk.ua. ### Your scale. Your energy system. ### BESS for commercial sites Backup for retail, offices, filling stations and small production facilities. We establish critical loads, autonomy and installation requirements. ### Industrial BESS / ESS Energy storage for manufacturing, agriculture and logistics. Combine backup, peak limitation and consumption management through EMS. ### Containerised energy storage Large-scale systems for energy-intensive businesses and generation projects. Capacity, grid connection and market participation require individual assessment. ### Solar generation + BESS Use more of your own solar energy. Coordinate PV generation, storage, the grid and your existing generator. ### Transformers and substations Power infrastructure for storage, generation and business expansion. Selected to match the connection scheme and technical requirements. ### Online UPS and batteries Specify an online UPS, batteries and accessories for your critical load and backup duration. From a server rack to a production line, we prepare an agreed equipment specification and quotation. ## Transformers and power infrastructure Source: https://bess.com.ua/en/solution-transformers.html Language: en ### Power transformers and substations: selection and supply Transformers, compact substations and switchgear for BESS and industrial sites. Select by kVA, voltage, losses and equipment scope with USK Energy. ### What we agree before ordering We select equipment against your parameters and manufacturer requirements. The quotation defines the equipment package, options and supply terms. - Load profile, operating objectives and required autonomy - Compatibility with the grid, generator, PV and control systems - Installation conditions, protection, cooling and service access - Supply scope, documentation, warranty terms and logistics ### Equipment for connection and integration Transformers, substations, distribution and protection in the USK ENERGY catalogue. Select a transformer by apparent power in kVA, voltages, operating conditions and network parameters. A load’s active power in kW cannot be substituted directly for the transformer kVA rating. ### What to include in your enquiry For an initial estimate, S = P / PF: 500 kW at a power factor of 0.9 is approximately 556 kVA before allowance and other checks. Final selection also considers harmonics, temperature, overload and protection requirements. ### What to compare in quotations Specify primary and secondary voltages, vector group, short-circuit voltage, losses, construction, tap adjustment and accessories. Distinguish the transformer price from a complete substation and network connection. USK Energy — Equipment for your application B2B.engineer ### Start with the essentials. BESS stores energy and manages its use. A UPS primarily maintains power quality and continuity. Loads that cannot tolerate a break require separate verification of UPS topology and BESS compatibility. Consumption profile, critical power, required autonomy, electricity contract, electrical diagram and information on PV or a generator. Start with the project brief; we will clarify any missing data. No. Savings depend on the use case, energy prices, charging mode, losses and equipment life. A financial model based on verified inputs is needed before ordering. The specification defines the main equipment, batteries, options, documentation, warranty terms and logistics. Installation work is not included in the equipment supply unless expressly stated in the contract. BESS.COM.UA is USK Energy B2B platform for industrial storage, ESS, uninterrupted power and energy efficiency. The ecosystem’s main website is usk.ua. ### Your scale. Your energy system. ### BESS for commercial sites Backup for retail, offices, filling stations and small production facilities. We establish critical loads, autonomy and installation requirements. ### Industrial BESS / ESS Energy storage for manufacturing, agriculture and logistics. Combine backup, peak limitation and consumption management through EMS. ### Containerised energy storage Large-scale systems for energy-intensive businesses and generation projects. Capacity, grid connection and market participation require individual assessment. ### Solar generation + BESS Use more of your own solar energy. Coordinate PV generation, storage, the grid and your existing generator. ### Transformers and substations Power infrastructure for storage, generation and business expansion. Selected to match the connection scheme and technical requirements. ### Online UPS and batteries Specify an online UPS, batteries and accessories for your critical load and backup duration. From a server rack to a production line, we prepare an agreed equipment specification and quotation. ## Online UPS and batteries Source: https://bess.com.ua/en/solution-ups.html Language: en ### Online UPS for business: equipment selection and supply Specify an online UPS, batteries and accessories for your critical load and backup duration. From a server rack to a production line, we prepare an agreed equipment specification and quotation. ### An equipment package for continuous power A supply enquiry starts with the load list, rather than the UPS rating alone. The quotation identifies the equipment, batteries, options, warranty terms and agreed delivery schedule separately. ### Online UPS systems Single-phase 1–10 kVA, three-phase equipment in the 10–40 and 60–200 kVA ranges, and modular systems in the 300–600 kVA class. Rack, tower and convertible formats are selected for the location and load. ### Batteries and cabinets VRLA AGM lead-acid batteries, external battery modules, cabinets and racks. Selection covers DC voltage, discharge performance, batteries per string and charger capability. ### Bypass, protection and monitoring Maintenance bypass, battery disconnects and fuses, cable kits, SNMP, dry contacts and other interfaces, subject to compatibility with the selected model. COVER by Comex is one option in our selection. We also consider other manufacturers and equivalent equipment against your requirements. A modular cabinet rating is not the installed power: the module population and redundancy are specified separately. ### Why choose an online UPS In double-conversion mode (AC → DC → AC), the UPS inverter supplies the load. When input power fails, the battery supplies the DC link while the inverter continues operating. Manufacturers specify no transfer interruption to battery in this mode. This does not promise continuity through every fault: overload, equipment failure, ECO and bypass operation have different conditions. ### Online UPS + LiFePO4 BESS: complementary backup roles The UPS supports the critical circuit during transfer; a BESS can provide longer backup. LiFePO4 describes the battery chemistry. Transfer delay is determined by the PCS, transfer switch, controls and operating mode. - 01 Utility / BESS backup supply - 02 Online UPS + its own VRLA batteries - 03 Critical load Functional sequence for equipment selection. UPS and BESS batteries remain separate systems; a shared DC connection is not assumed. The BESS must support island operation, and its output must meet the UPS input requirements. ### Before utility failure The UPS runs in double-conversion mode with batteries ready for backup. ### During source transfer The UPS battery supports its inverter. Required runtime covers both transfer switching and the time for the backup source to become ready. ### Once the BESS is ready The UPS accepts the backup input once voltage and frequency are within its limits. BESS power must cover the load, losses and the agreed battery charging demand. ### What to include in a pricing enquiry ↔ Scroll horizontally to see every column. ### Lead-acid batteries matched to backup duty VRLA AGM is an option for short-duration online UPS backup. Frequent outages make discharge depth, frequency and recharge time important. An Ah rating at a 10- or 20-hour discharge rate does not establish the power available for 5–15 minutes. A quotation needs discharge data for the actual battery; LiFePO4 is not a drop-in replacement for a lead-acid bank without confirmed UPS and BMS compatibility. ### More equipment across the USK ecosystem Compare categories and send a model, specification or parameter list to request an equivalent. ### Before ordering ### Online UPS for hospitals: VRLA batteries with LiFePO4 BESS backup Specify hospital online UPS equipment when a BESS has a transfer delay: critical circuits, VRLA AGM batteries, runtime, bypass and compatibility for a supply enquiry. ### Online UPS for industry: adding VRLA backup alongside a BESS What to buy for PLC, HMI and industrial network protection during BESS transfer: online UPS, VRLA AGM, bypass and monitoring. Compare complete equipment packages. ### Questions Only if the specific system meets the permissible interruption, power-quality and operating requirements of the critical equipment. Large capacity and LiFePO4 chemistry do not prove uninterrupted transfer. A separate online UPS is often considered for sensitive circuits. Yes, battery-free configurations can be selected. State whether you need batteries, an external cabinet, bypass and connection kits. Existing battery-bank compatibility must be checked against manufacturer specifications. No. COVER / Comex is one option. We select equipment and alternatives from different manufacturers against requirements for power, runtime, format, interfaces and warranty. Power rating, topology, phases, modularity and redundancy, battery type and quantity, cabinets, bypass, monitoring and logistics. Compare the complete agreed package rather than the base unit price alone. Equipment is selected for particular loads and the requirements of the medical location. An online label alone does not establish compliance of the installation. An enquiry should include the designer’s requirements and those of the medical equipment manufacturers. ## BESS prices and quotation comparison Source: https://bess.com.ua/en/tsiny-bess.html Language: en ### BESS price in Ukraine: equipment scope and quotation What determines industrial BESS pricing: kW, kWh, PCS, EMS, protection and delivery. Compare equipment scope and request a USK Energy quotation. A BESS price describes an agreed configuration, not just a number of kilowatt-hours. A useful quotation requires load power, backup duration, operating mode and connection voltage. USK Energy supplies equipment to specification; the quotation defines price, VAT, delivery and lead time. ### Why a price per kWh is not enough Two 400 kWh systems can have different PCS ratings, usable state-of-charge windows and backup capabilities. Supplying 200 kW for two hours requires 400 kWh at the load. Battery nameplate capacity must also account for losses, the operating SOC window, temperature and retained capacity at the agreed point in service life. A low battery-cabinet price is not the price of a complete system. Check whether PCS, controls, switching, thermal management, protection and the options required by your electrical arrangement are included. ### Ask for separate line items Battery modules and BMS; PCS with the required operating modes; EMS and monitoring access; enclosure and thermal management; switching, protection and hazard detection; a transformer if needed; documentation, spare parts and delivery. Each item needs a model, quantity and clear supplier responsibility. Separate installation, design, connection and acceptance testing from the equipment price. Their scope depends on the site; there is no universal percentage to add to every BESS quotation. ### Make quotations comparable Give each supplier the same requirements: critical kW, backup hours, load profile, voltage, existing PV and generator, permissible interruption and installation conditions. Mark missing information explicitly so assumptions are visible in the quotation. Compare usable AC energy under the same conditions. Clarify warranty limits expressed in years, cycles or energy throughput, together with temperature and duty restrictions. A cycle count without test conditions does not describe the delivered system’s service life. ### Where a price comparison can mislead Check currency, VAT, delivery destination, unloading, quotation validity and recurring licence charges. Availability and lead time are confirmed for the selected configuration. An online calculation does not check warehouse stock. An economic assessment also needs losses, auxiliary consumption, ageing, maintenance and financing. Tariff shifting only works when the avoided energy cost exceeds these costs. Energy reserved for an outage cannot simultaneously be counted in full as available for daily savings. Technical reference — DOE/FEMP: BESS Procurement Checklist USK Energy — Equipment for your application B2B.engineer ## How to select BESS Source: https://bess.com.ua/en/yak-obraty-bess.html Language: en ### How to choose a BESS supplier: 14 checks to make before the deposit Which certificates a storage supplier must show, how to verify what cells are inside, what a warranty has to state, why "10 years" without MWh means… An industrial battery system is a fifteen-to-twenty-year purchase in which half the risk is not in the equipment but in whether anyone will still be servicing it in year five. Below is a list a technical director can work through without hiring a consultant. ### Key parameters ### Documents a supplier should send without hesitation Not "after an NDA", not "the manufacturer has it" — a PDF in reply to an email. If one of these is missing, that is information in itself. ↔ Scroll horizontally to see every column. On IEC 62443 in particular: if the control system has remote access — and it almost always does, otherwise there is no monitoring — this is not a formality. A battery reachable from outside is part of your industrial network, and its vulnerabilities become yours. The minimum worth demanding: a separate VLAN, no default passwords, signed firmware updates. More in the storage cyber security article . ### Cells: how to verify what is inside The most expensive part of the system and the easiest place to save money invisibly. Three questions settle it. First: who made the cell and which model? Not the system brand — the cell. The answer should be specific: manufacturer, model, nominal capacity in ampere-hours. "Lithium iron phosphate from a leading Chinese manufacturer" is not an answer. Second: new cells or second-life? A market for used EV cells exists and in some applications they are justified — but the price should reflect it. Ask about grade directly: A-grade (new, full datasheet), B-grade (parameter deviation), second-life (after a first life). The price gap between A and B runs to tens of percent, and so does the difference in service life. Third: what is the manufacturing date? Lithium cells age on the shelf. A cell made two years ago and stored in less than ideal conditions has already lost part of its life. A normal interval from manufacture to commissioning is up to six months. How to read the datasheet itself is covered on the cell chemistry page : five fields that determine the real life of the system. ### Warranty: for what, and under which conditions A warranty in years with no mention of energy means nothing. Batteries degrade with cycles, not with the calendar. "10-year warranty" without qualification lets the supplier decline if you ran two cycles a day instead of one. The correct wording looks like this: "retention of at least 70 % of initial capacity for 10 years or 25 MWh of throughput, whichever comes first, when operated within a 10–90 % SOC window at 15–30 °C" . - The capacity threshold. 70 % or 80 % — a difference of two to three years of real life. - Operating conditions. SOC window, temperature, maximum C-rate. If your duty falls outside them, the warranty does not apply. - What the supplier actually does when a claim succeeds: replace a module, top up the lost capacity, or refund. Three different obligations. - Who pays for the work. The cell may be free while removal, shipping and installation are yours. It has to be written down. Separately: the converter warranty is usually shorter than the battery warranty — five years against ten. That is normal, but it should be visible in the quote rather than discovered in year seven. ### Service: the question people ask last and should ask first - Who physically turns up. Company name, city, number of engineers. "A service partner in Ukraine" without specifics is not an answer. - Response time in the contract. Not "promptly" but hours to a response and days to a site visit, split between critical and non-critical faults. - Spare parts held. Which items sit in stock in Ukraine: module, fan, controller, BMS board. And the lead time for what does not. - Access to the control system. Whether you, or a third-party contractor, could maintain the system if the supplier disappeared. Closed protocols and a hard dependency on the manufacturer's cloud are a real risk over ten years. The last point is the most underestimated. Ask directly: can EMS data be exported in a standard format, is there a local web interface, does the system work when the manufacturer's cloud is unreachable. "Everything goes through our app" means you are tied to that company for the life of the asset. ### Red flags in a quotation Wording that deserves a follow-up question. None of it proves bad faith — each of them means something has been left unsaid. And one note about ourselves, so the list is honest: we supply equipment and organise turnkey installation — design, delivery, commissioning and service are carried out by our team and vetted contractors, with the exact scope and schedule agreed by a manager according to location and situation. We do not call ourselves the official distributor of any brand and do not promise a free engineer visit before the scope is agreed. If a quotation carries all three promises at once, ask for the documents behind each. A checklist for your own review is in the block below. Tick what the supplier has already closed; whatever stays unticked is your agenda for the next meeting. ### Check your own quotation Fourteen points that close most of the risk. Tick what the supplier has confirmed with a document rather than a sentence. Nothing checked yet. Start with the cell datasheet — it answers several questions at once. ### Frequently asked questions Figures shown are indicative. We supply the equipment and size the system; design, installation and commissioning are arranged through contractors when needed and quoted separately. Exact sizing follows a load-profile analysis. ## Commercial terms Source: https://bess.com.ua/en/terms.html Language: en ### Terms of Service and provision of services Terms of service, SLA and warranty obligations of USK ENERGY / BESS. EPC contracting of industrial energy storage systems. Editorial from 01.01.2026. Valid for all B2B orders through bess.com.ua These Terms of Service (hereinafter referred to as "Terms") regulate the procedure for interaction between USK ENERGY / BESS (hereinafter referred to as the "Executor") and corporate Customers (LLC, FOP) when ordering services for the design, supply and commissioning of industrial energy storage systems (BESS) through the bess.com.ua website and related communication channels. ### 1. Subject of the Agreement The contractor provides comprehensive EPC contracting services (Engineering, Procurement, Construction) in the field of industrial battery energy storage systems with a capacity from 30 kW to 5+ MW: - Engineering (Design): Feasibility study, development of project documentation of the P/R stage, one-line schemes, calculation of ROI and payback period. - Procurement (Supply): Procurement and logistics of equipment from Tier-1 manufacturers (CATL, EVE Energy, Deye, Pylontech), customs clearance, warehouse storage in Kyiv. - Construction (Montage): Chief installation, commissioning works, integration of the existing power grid of the facility, connection to ASKOE. - Warranty service: Technical support, monitoring the state of battery modules, planned replacement of components according to the warranty card. ### 2. Order procedure The customer submits an application through one of the channels: a form on bess.com.ua (TEO request, Configurator, Partner application), AI consultant on the site, e-mail sales@usk.ua or Telegram bot. Submitting an application is not a contractual obligation. Within 24 working hours of receiving the application, the Contractor's engineer contacts the Customer to clarify the technical parameters: object type, load capacity, current tariff, consumption profile, presence of a transformer substation. Based on the received data, the Contractor prepares a Technical and Commercial Proposal (TCP) with details: equipment specification, estimate, work schedule, ROI calculation. TKP is provided free of charge. In the case of agreement on the TCP, the parties sign a Supply Agreement and/or a Subcontract Agreement. Payment is made in stages: advance (30-50%), payment upon shipment (30-40%), final payment after commissioning (10-30%). ### 3. SLA — Service Level The contractor guarantees the following service quality parameters for all projects: ↔ Scroll horizontally to see every column. ### 4. Warranty Obligations LiFePO4 battery modules produced by CATL / EVE Energy have a warranty of 10 years or 6000 full charge-discharge cycles (whichever comes first). The remaining capacity at the end of the warranty period is at least 70% of the nominal capacity (SOH ≥ 70%). Deye hybrid inverters have a manufacturer's warranty of 5 years with the possibility of extension to 10 years by additional agreement. The contractor provides warranty service on the territory of Ukraine. - Mechanical damage caused by the Customer or third parties. - Operation of the equipment in conditions that do not correspond to the technical documentation (temperature regime, humidity, electrical parameters). - Tampering with the hardware or software without the written permission of the Contractor. - Natural disasters, military operations (force majeure). ### 5. Liability of the Parties - Perform work in accordance with the agreed TKP and project documentation. - Only use certified equipment with compliance documents. - Ensure the confidentiality of the Customer's technical data (see Privacy policy ). - Provide a complete set of executive documentation after completion of work. - Provide reliable technical data for design (one-line diagrams, ASKOE data, TP parameters). - Provide access to the facility for installation work within the agreed time frame. - Follow the Contractor's recommendations regarding equipment operation. - Make payment in accordance with the schedule determined by the Agreement. ### 6. Use of the Website The bess.com.ua website features an AI-based AI advisor that provides preliminary BESS configuration recommendations. AI's responses are for informational purposes only and do not constitute an offer or contractual obligation. Final technical parameters and prices are agreed upon by the engineer. The online configurator (quiz) on the website helps to determine the optimal type of BESS for the Customer's object. The result of the configurator is a preliminary recommendation; the exact specification is determined after the engineering survey. The articles in the "Engineering Digest" section are educational and analytical in nature. The contractor is not responsible for decisions made solely on the basis of published materials without prior engineering consultation. ### 7. Intellectual Property All materials on bess.com.ua (texts, graphics, calculation models, project documentation) are the intellectual property of the Contractor or are used on the basis of license agreements. The customer receives the right to use project documentation exclusively for the implementation of a specific project specified in the Agreement. ### 8. Force majeure The parties are released from responsibility for partial or complete non-fulfillment of obligations, if it is the result of force majeure circumstances: hostilities, natural disasters, decisions of state bodies restricting economic activity, interruptions in the work of international logistics. The term of performance of obligations is extended for the period of force majeure. ### 9. Resolution of Disputes Disputes are resolved through negotiations. In case of failure to reach an agreement, in accordance with the current legislation of Ukraine. Jurisdiction — commercial court at the location of the Executor (Kyiv). ### 10. Changes to the Terms The Contractor reserves the right to make changes to these Terms. The current edition is always available at bess.com.ua/terms.html . For existing Contracts, changes become effective only after written approval by the Customer. ### 11. Contact USK ENERGY / BESS sales@usk.ua